1001 Relay Normally Close Failure of Grid

Fault Description:


The grid relay is still closed when the relay open signal is sent . It maybe caused by Grid relay contact adhesion or grid relay demage. 


if this issue happened , the aPower will go safety mode while the grid outage . because the Franklin home power can not go island ,  


Past Fixes:


replace the damage grid relay .



Troubleshooting Actions:


Turn off the service breaker ,  if the error code still show  "1001 Relay Normally Close Failure of Grid" ,and aPower enters the fault protection state, so there is contact adhesion issue with the Grid relay . 